Shutter Cabinet Drawings in Different Units: Preparing Metric and Imperial Details for Global Buyers
Mixed metric and imperial drawings are a quiet source of errors in slatted cabinet orders. This guide shows how to handle slat pitch, track clearance and door sizing so the factory builds what you drew.
Getting shutter cabinet drawing units right is one of the simplest ways to avoid remakes on a hotel project. A tambour or louvred door is built from many small repeating parts, so a rounding habit that is harmless on a plain panel can add up across a whole door. This guide explains where metric and imperial drawings go wrong and how to prepare a drawing set that a factory can quote and build without guessing.
Why units matter more on slatted doors
On a hinged door, a 1 mm error in width is usually absorbed by the gap around it. On a shutter door, the slats, the track and the roller housing all work together, and each has its own tolerance. A small error in one dimension can show up as a sticking door, uneven slat reveals or a door that does not fully retract.
Hotel joinery is also commonly drawn by one team and built by another in a different country. Architects may work in feet and inches, the interior designer in millimetres, and the factory in millimetres. Every hand-off is a chance for a conversion error.
The three dimensions that cause most errors
1. Slat pitch
Slat pitch is the centre-to-centre distance between neighbouring slats. It controls how many slats fit in a given door height and how the door looks when closed. It is often confused with slat width, which is the visible face of a single slat.
When pitch is quoted in fractions of an inch, such as 1-1/2 in, the metric equivalent is 38.1 mm. A factory working to a round 38 mm pitch will produce a door that is slightly different in total height. Over thirty or forty slats, the difference becomes visible and may stop the door lining up with neighbouring cabinets.
Decide which value is the master. If the design intent is 1-1/2 in, state the metric figure to one decimal place and note that the metric value governs for production.
2. Track clearance
The track or guide channel must hold the slat ends with enough room to move freely, but not so much that the door rattles. Clearances are often only a few millimetres, so they are the most sensitive dimension in the set.
Fractions such as 1/8 in (3.2 mm) are frequently rounded to 3 mm or 4 mm by different people. Rounding in the wrong direction can make a door bind in humid conditions or rattle at night. Write track clearance as a toleranced value in the master unit, for example a nominal figure with a plus or minus range, and avoid leaving it as a note on a conversion table.
3. Door sizing and opening dimensions
Door width and height are normally derived from the cabinet opening, less allowances for the track, the roller housing and the fit gap. If the opening is given in imperial and the allowances in metric, the final door size is easy to get wrong.
Always state whether a dimension is the nominal opening, the finished door size or the cut size. A single drawing that mixes these without labels is a common cause of doors made too large or too small.
A practical conversion reference
Use this table as a starting point for common slatted cabinet values. Always confirm exact figures against your own drawings.
| Imperial | Exact metric | Common rounded value | Risk when rounded |
|---|---|---|---|
| 1/16 in | 1.6 mm | 1.5 or 2 mm | Slat gaps and edge reveals |
| 1/8 in | 3.2 mm | 3 mm | Track clearance |
| 1/2 in | 12.7 mm | 12 or 13 mm | Slat thickness, panel build-up |
| 1 in | 25.4 mm | 25 mm | Cumulative error over many slats |
| 1-1/2 in | 38.1 mm | 38 mm | Total door height over a full slat run |
| 24 in | 609.6 mm | 600 mm | Fit inside opening, 9.6 mm difference |
The last row is worth noting. Many regions treat 24 in and 600 mm as interchangeable modules, but they are not the same size. A cabinet designed around a 24 in appliance or opening will not accept a door built to a 600 mm module.
Choose one master unit per project
The most reliable approach is to pick a single master unit for production and make every other value a reference. For most factory work, including ours in Istanbul, millimetres are the natural working unit. That does not stop you from drawing in inches for your own team.
A clean way to do this:
- State the master unit in the title block, for example: all dimensions in millimetres unless noted.
- Show the secondary unit in brackets on key dimensions only, such as 38.1 mm (1-1/2 in).
- Avoid dual dimensioning on every line, which clutters the drawing and hides errors.
- Give tolerances in the master unit.
Convert once, at the source
Repeated conversion is where errors multiply. If an imperial design is converted to metric for the factory, and then the factory's shop drawings are converted back to imperial for approval, rounding errors can compound.
Convert once, check it, and carry the metric figures forward. If the designer needs to review in inches, have the factory add inch references in brackets to the shop drawings rather than redrawing them.
Slat dimensions in inches: what to specify
If your team describes slat dimensions in inches, provide the following for each model:
- Slat width and thickness, with the decimal equivalent, not only fractions.
- Slat pitch, clearly labelled as centre-to-centre.
- Slat length or number of slats per door.
- Profile shape, such as flat, rounded or grooved.
- Finish and edge treatment.
Decimal inches are easier to convert than fractions, so use them where you can. Where a fraction is used, add the millimetre value beside it.
Hotel joinery dimensions beyond the door
The shutter door is only one part of the unit. Hotel joinery dimensions around it also need to be consistent: carcass depth, plinth height, shelf positions, roller housing depth and wall gaps. If the carcass is drawn in one unit and the door in another, tolerances at the interface are easy to miss.
Check these points before releasing drawings:
- Opening width and height match the door size plus allowances.
- Roller housing or top box depth is stated in the master unit.
- Clearance between door travel and any internal shelf or appliance is shown.
- Wall and ceiling gaps are labelled as design values, not site assumptions.
On site, floors, walls and ceilings are rarely perfect, so allow a note about scribing or adjustment and state who is responsible for field measurements.
Preparing a drawing set for global buyers
A clear drawing set reduces back-and-forth, and it helps when you compare offers from different factories. When you send drawings for quotation, include:
- Plan, elevation and section views of each unit.
- A schedule listing model code, quantity, door size and slat details.
- The master unit, a note on tolerances and any imperial reference values.
- A short legend explaining abbreviations.
- Finish references and sample requirements.
Send editable files such as DWG or DXF if you can, together with a PDF so the factory can see the intended presentation. If you only have a PDF, scaled drawings with clear dimensions are still workable.
Use the mock-up room to verify units
Even a perfect set of drawings can hide a conversion mistake. A mock-up room is the cheapest place to find it. Measure the finished door against the drawing, check slat pitch with a rule in both units, and operate the door several times to see whether track clearance is correct.
If a unit conversion error appears at this stage, correct the master drawing and update every affected sheet, not only the sample.
A short checklist before you send drawings
- Is the master unit stated in the title block?
- Are slat pitch, slat width and track clearance given with decimals and tolerances?
- Are nominal opening, finished door size and cut size labelled separately?
- Have any 24 in or 600 mm assumptions been checked against the real opening?
- Has each conversion been made only once and checked?
- Are the schedule and drawings consistent with each other?
Next step
If you are preparing drawings for a hotel project in any region, send them to us even if the units are mixed. We will review the slat pitch, track clearance and door sizes, point out anything that needs clarifying and return shop drawings in a consistent master unit for your approval.
Sıkça Sorulan Sorular
Should I send shutter cabinet drawings in metric or imperial?
Either is acceptable, but state one master unit in the title block. We work in millimetres, so metric values usually govern production. If your team prefers inches, add them in brackets on key dimensions such as slat pitch and door size, and we will confirm the conversions on shop drawings.
Why is slat pitch so important in unit conversion?
Slat pitch repeats across the full door height, so a small rounding difference multiplies. A pitch of 1-1/2 in is 38.1 mm, and rounding it to 38 mm changes total height over many slats. Specify the master value to one decimal place.
Is 24 inches the same as 600 mm for cabinet openings?
No. 24 in is 609.6 mm, about 10 mm larger than 600 mm. Some regions use them interchangeably as module sizes, but a door built for one may not fit an opening made for the other. Always confirm against the actual opening.
How do I describe track clearance on a drawing?
Give it as a nominal value with a tolerance in the master unit, and label it clearly as clearance, not as a gap or reveal. Avoid fractions without decimals, because rounding of small clearances can cause binding or rattle.
Can the factory convert my imperial drawings for me?
Yes, we can prepare shop drawings in millimetres with inch references in brackets. You should still review the converted values, especially slat pitch, track clearance and finished door size, before approving production.
Every hotel project is different. Send us your drawings or room schedule for a tailored proposal on materials, lead time and shipping.